RH-E107 12.1" color TFT Touch Screen Monitor ICU for Hospital
Product Description
12.1" color TFT touch screen
Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available.
Supporting wire or wireless network.
Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.
Specifications
Lead Mode | 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) |
Lead selection | I, II, III, avR, avL, avF, V |
Wave form | 2 ch |
Lead mode | 3 Leads ( R, L, F or RA, LA, LL) |
Lead selection | I, II, III, |
Wavef orm | 1 ch |
Gain | 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto |
HR and Alarm Range | Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm |
Accuracy | ±1% or±1bpm, which is greater |
Resolution | 1 bpm |
Sensitivity | > 200 (uVp-p) |
Differential Input Impedance | > 5 MΩ |
CMRR | Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB |
Electrode offset potentia | ±300mV |
Leakage Current | < 10 uA |
Baseline Recovery | < 3 S After Defi. |
ECG Signal Range | ±8 m V ( Vp-p ) |
Bandwidth | Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz |
ECG Signal Range | ±8 m V ( Vp-p ) |
Bandwidth | Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz |
ARR Detecting | Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available |
Respiration | |
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | > 2.5 MΩ |
Measuring Impedance Range | 0.3~3 Ω |
Base line Impedance Range | 200~4 KΩ |
Bandwidth | 0.1~2.5Hz |
Resp. Rate | Measuring and Alarm Range Adult 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 Brpm |
Apnea Alarm | 10 ~ 40 S |
NIBP | |
Method | Oscillometric |
Mode | Manual, Auto, STAT |
Measuring Interval in AUTO Mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) |
Measuring Period in STAT Mode | 5 Min |
Pulse Rate Range | 40 ~ 240 bpm |
Alarm Type | SYS, DIA, MEAN |
Measuring and alarm range | Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg |
Resolution | 1mmHg |
Accuracy | Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg |
Overpressure Protection | Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg |
SpO2 | |
Measuring Range | 0 ~ 100 % |
Alarm Range | 0 ~ 100 % |
Resolution | 1 % |
Accuracy | 70% ~ 100% 2 % 0% ~ 69% unspecified |
Actualization intervalabout | 1 Sec. |
Alarm Delay | 10 Sec. |
Pulse Rate | Measuring and Alarm Range 20~300 bpm Resolution 1bpm Accuracy ±3bpm |
TEMP | |
Channe | 2 |
Measuring and Alarm Range | 0 ~ 50 ºC |
Resolution | 0.1 ºC |
Accuracy | ±0.2 ºC |
Actualization intervalabout | 1 Sec. |
Average Time Constant | < 10 Sec. |
IBP | |
Label | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and alarm range | ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg |
Press Sensor | Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω |
Resolution | 1 mmHg |
Accuracy | ±2% or 1mmHg which is greater |
Actualization interval | about 1 secretary |
Type
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
RH-E107 12.1" color TFT Touch Screen Monitor ICU for Hospital
Product Description
12.1" color TFT touch screen
Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available.
Supporting wire or wireless network.
Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.
Specifications
Lead Mode | 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) |
Lead selection | I, II, III, avR, avL, avF, V |
Wave form | 2 ch |
Lead mode | 3 Leads ( R, L, F or RA, LA, LL) |
Lead selection | I, II, III, |
Wavef orm | 1 ch |
Gain | 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto |
HR and Alarm Range | Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm |
Accuracy | ±1% or±1bpm, which is greater |
Resolution | 1 bpm |
Sensitivity | > 200 (uVp-p) |
Differential Input Impedance | > 5 MΩ |
CMRR | Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB |
Electrode offset potentia | ±300mV |
Leakage Current | < 10 uA |
Baseline Recovery | < 3 S After Defi. |
ECG Signal Range | ±8 m V ( Vp-p ) |
Bandwidth | Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz |
ECG Signal Range | ±8 m V ( Vp-p ) |
Bandwidth | Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz |
ARR Detecting | Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available |
Respiration | |
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | > 2.5 MΩ |
Measuring Impedance Range | 0.3~3 Ω |
Base line Impedance Range | 200~4 KΩ |
Bandwidth | 0.1~2.5Hz |
Resp. Rate | Measuring and Alarm Range Adult 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 Brpm |
Apnea Alarm | 10 ~ 40 S |
NIBP | |
Method | Oscillometric |
Mode | Manual, Auto, STAT |
Measuring Interval in AUTO Mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) |
Measuring Period in STAT Mode | 5 Min |
Pulse Rate Range | 40 ~ 240 bpm |
Alarm Type | SYS, DIA, MEAN |
Measuring and alarm range | Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg |
Resolution | 1mmHg |
Accuracy | Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg |
Overpressure Protection | Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg |
SpO2 | |
Measuring Range | 0 ~ 100 % |
Alarm Range | 0 ~ 100 % |
Resolution | 1 % |
Accuracy | 70% ~ 100% 2 % 0% ~ 69% unspecified |
Actualization intervalabout | 1 Sec. |
Alarm Delay | 10 Sec. |
Pulse Rate | Measuring and Alarm Range 20~300 bpm Resolution 1bpm Accuracy ±3bpm |
TEMP | |
Channe | 2 |
Measuring and Alarm Range | 0 ~ 50 ºC |
Resolution | 0.1 ºC |
Accuracy | ±0.2 ºC |
Actualization intervalabout | 1 Sec. |
Average Time Constant | < 10 Sec. |
IBP | |
Label | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and alarm range | ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg |
Press Sensor | Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω |
Resolution | 1 mmHg |
Accuracy | ±2% or 1mmHg which is greater |
Actualization interval | about 1 secretary |
Type
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder